Basic Info.
Model NO.
Type I(inactivation); Type II(non inactivation);
Type
Test Strips & Test Tube
Ethylene Oxide Sterilization
Without Ethylene Oxide Sterilization
Quality Guarantee Period
Two Years
Logo Printing
Without Logo Printing
Specification
5ml; 10ml; 20ml
Product Description
Product Description
Single use virus sampling tube inactivation type manual
product name:
Generic name: single-use virus sampling tube
English name: Disposable virus sampling tube
[Packaging specifications] 50 servings/box & 800 servings/box
expected usage:
It is used for the collection and transportation of clinical influenza, avian influenza, hand, foot and mouth disease, measles and other virus specimens, as well as chlamydia, mycoplasma, and ureaplasma specimens.
Main components:
Serial number Composition 50 servings/box 800 servings/box
1 Preservation tube (including 3ml inactivated or non-inactivated preservation solution) 3ml×50 tubes 3m1×800 tubes
2 Throat swabs or nasal swabs 50 pieces/box 800 pieces/box
3 Instructions
[Storage conditions and validity period] Normal temperature is 5~25ºC, and the validity period is 12 months.
Sample requirements:
1. Applicable sample types: clinical samples such as nasopharyngeal swabs, saliva, sputum, etc.;
2. Sample storage and transportation: samples should be transported to the corresponding laboratory for testing within 48 hours after collection, and the storage temperature is 2~8ºC: if they cannot be transported to the laboratory within 48 hours, they should be stored at -20ºC or below , Sent to the corresponding laboratory within one week. Samples should avoid repeated freezing and thawing.
Instructions:
1. Mark relevant sample information on the sampling tube.
2. According to different sampling requirements, use the sampling swab to sample at the corresponding site, hold the handle and gently insert the sampling swab into the sampling site, gently rotate the sampling swab 3-5 times, and then take it out slowly.
3. Put the extracted sample into the sampling tube, break the swab at the breaking point of the swab at the edge of the tube, leave the brush head in the tube, and then tighten the tube cap and seal it to complete the sampling.
4. Freshly collected clinical specimens should be transported to the laboratory within 48 hours under chemistry. If they cannot be delivered to the laboratory within 48 hours, they should be stored at -20°C or below. The specimens should be separated as soon as possible after being sent to the laboratory. Those that can be inoculated and separated within hours can be stored at 4C. If not inoculated, it should be stored at -20ºC or below.
5. Conventional sampling methods are as follows:
a) Nasal swab: Gently insert the swab head into the nasal palate in the nasal passage, stay for a while and then slowly turn the line to exit. Swab the other nostril with another swab, immerse the swab head in the sampling solution, and discard the tail.
b) Pharyngeal swab: Use the swab to wipe the bilateral pharyngeal tonsils and posterior wall of the pharynx. Similarly, immerse the swab head in the sampling solution and discard the tail.
c) Mouthwash: Use 10mL of normal saline to gargle. When rinsing, make the patient's head tilt back slightly, make an "oh" sound, let the normal saline rotate in the pharynx, and collect the lotion with a 50mL empty sample tube.
d) Nasal lotion: The patient takes the sitting woman, tilts his head slightly back, and uses a pipette to inject 50 mL of normal saline into one nostril, and asks the patient to make a K sound at the same time to close the pharyngeal cavity. Then let the patient lower his head to let the saline flow out, collect the lotion with a 50mL empty sampling tube, and repeat the process to wash both nostrils.
e) Nasopharyngeal aspiration: tracheal and bronchial secretions are often collected by this method, and mucus is extracted from the nasopharyngeal area with a collector connected to a negative pressure pump. First insert the collector head into the nasal cavity, turn on the negative pressure, rotate the collector head and slowly push it out. Collect and extract the mucus and rinse the collector three times with 5 mL of the collection fluid.
f) Autopsy tissue specimens: If necessary, collect autopsy tissue specimens for sample component separation. The specimen is autopsy tissue.
g) Sampling of mycoplasma, chlamydia, and ureaplasma specimens: male: insert a sterile cotton swab into the urethra about 2cm, rotate it, and stand still for several seconds to collect the material. Female: Wipe off the cervical mucus, insert a sterile swab into the cervical canal 1-2cm to get the material. To
Precautions:
1. The disposable sampler should be transported at a low temperature of 2-8ºC and sent for inspection immediately after sampling. The collected samples can be placed at 2-8°C for a short period of 48 hours; long-term storage should be placed under low temperature conditions below -20°C to avoid repeated freezing and thawing.
2. The product is strictly prohibited to be used for the sampling of bacterial samples, and the antibiotic contained in the preservation solution itself has an inhibitory effect on bacteria.
3. It is forbidden to directly contact the collected patient, and to sample the patient after wetting the swab.
4. Strictly follow the sampling procedures when collecting samples to ensure that the sampling location is accurate and the sampling intensity is uniform and suitable, otherwise the sample quality will be affected.
5. The product must not be used after the expiry date or the product packaging is damaged. To
Validity:12 months
Detailed Photos
Address:
Room 1002-2, No. 746 Taikang Middle Road, Yinzhou District, Ningbo, Zhejiang, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Health & Medicine
Management System Certification:
ISO 13485, FSC
Company Introduction:
Ningbo Pinocare Medical Equipment Co., Ltd, located in the beautiful seaside city of Ningbo, is a vibrant medical products company that focus on production and sale of disposable medical devices. Relying on a strong R & D team composed of professional and technical personnel, advanced production equipment, first-class production technology and perfect quality system, We are committed to developing and producing high-quality and cost-effective products.
We also have reliable partners who are professional manufacturers of Respiratory&Anesthesiology supplies (oxygen mask, nebulizer, anesthesia breathing circuit, etc. ), surgical dressing, laboratory products and so on.
Sticking to the principle of "Customer First and Quality Foremost", we have established a comprehensive internal quality control system to improve our competitiveness in an all-round way. Our products are exported to Europe, America, Africa, the Middle East, Southeast Asia and other regions. Customers'frequent purchases is the best approval for us.
We are young and full of energy. We care for the human health, we care for ecological environment, we pay attention to sustainable development, and hope to create a better future with you.